LPO lowers the power draw of an optical module by 25 to 30 percent, by removing the signal processor from it. It sounds like an obvious decision, until you check what it requires in return. Linear optics is not a cheaper version of the classic module. It is a different division of responsibility between the module and the device the module works in. It works excellently in a narrowly defined scenario and does not work at all outside it. Below we explain where that boundary runs.
What the DSP does and why it draws half the module's power
The electrical signal coming out of a switch's ASIC is not suitable for driving a laser directly. It is distorted by the traces on the board, the connectors, and the port itself. The signal returning from the photodiode is distorted even more, because the path through the fibre has been added.
In a classic pluggable module, this problem is handled by the DSP signal processor. It reconstructs the shape of the signal, compensates for the distortions of the electrical and optical path, handles FEC error correction, and provides telemetry. It performs these operations in real time, at a bit rate counted in hundreds of gigabits per second.
That costs energy. It is assumed that the DSP signal processor consumes on average half the power used by the whole module. For an 800G module drawing 20 W, that means about 10 W for signal processing alone, before a single photon has even left the housing. Hence a simple conclusion that underlies the whole concept of linear optics: if the host ASIC can do this work itself, the DSP in the module is a duplication of function, paid for in watts and zloty.
Three architectures, not two
In sales conversations the usual opposition is DSP versus LPO. In reality there are three architectures, and the intermediate one is sometimes the most sensible choice.
Architecture
DSP in the module
Typical 800G draw
Requirement on the host
DSP full
full
20–30 W
none in particular
LROretimed optics
receive direction only
intermediate
partial
LPOlinear drive
none
11–15 W
an ASIC with path equalisation
In sales conversations the usual opposition is DSP versus LPO, but there are three architectures, and the intermediate one, that is LRO, is sometimes the most sensible choice between saving and integration risk.
DSP full is the default solution. The module is self-sufficient, works in any device supporting the given form factor and management standard. You pay the full energy price for universality. LRO removes the DSP from only one direction. The module still retimes the signal where it is most needed, and saves where the host can cope. It is a compromise between saving and integration risk. LPO removes the DSP entirely. The module becomes, in simplified terms, a linear amplifier driving the laser, and all the signal equalisation and error correction move to the SerDes block in the host ASIC. Hence the name, that is linear drive.
How much does it really save
The saving on a single module looks modest. Only multiplying by the number of ports shows the scale. The energy cost of a module is calculated by the formula: the module's power draw in kilowatts, multiplied by the number of ports, by 8760 hours in a year, by the facility's PUE efficiency factor, and by the energy price per kilowatt-hour.
Assumptions: 1000 x 800G ports, PUE 1.4, energy price 0.12 EUR/kWh, 8760 hours a year.
BASE VARIANT
DSP full
20 W per module
€29,434
energy per year
ECONOMY VARIANT
LPO
13 W per module
€19,132
energy per year
Annual difference
€10,302
plus a lower purchase price of the module by 15 to 25 percent and less heat emission
Over five years
over €51,000
at a thousand ports
It is worth noting the proportion, however. At a thousand ports we are talking about ten thousand euro a year. It is a real item in the operating budget, but it is not an amount that justifies taking on integration risk in a network where LPO is not fully verified. The saving takes on significance at tens of thousands of ports, that is at the scale at which cloud operators and large AI infrastructure providers operate.
What LPO requires in return
Here lies the heart of the decision. Removing the DSP from the module does not remove the work the DSP was doing. It moves it to the host.
1
The switch ASIC must support linear drive
Its SerDes block takes over the path equalisation and signal correction for the optics. Not every chip can do this, and the list of compatible solutions is markedly narrower than the list of devices that support ordinary pluggable modules. This is the first question to the switch manufacturer, not to the module supplier.
2
The electrical path between the ASIC and the port becomes part of the signal budget
In a module with DSP, the losses on the board traces and the connector were compensated by the processor in the module. In LPO the host compensates them, so the quality of the board design stops being irrelevant. Two switches with the same ASIC but a different port layout may behave differently.
3
Interoperability narrows
A module with DSP establishes a link with any standard-compliant module. In LPO the link behaviour depends on the host plus module pair, on both sides. A configuration that works in one environment is not automatically portable to another.
4
Diagnostics require a different approach
When a link is unstable, in a DSP architecture the cause lies in the module or in the optical path. In LPO a third possibility is added, that is the equalisation settings on the host side. This lengthens diagnosis and requires cooperation with the switch manufacturer.
When LPO makes sense, and when it is a risk
LPO makes sense when all four conditions are met at once.
LPO makes sense when all four conditions are met at once
01Scale in the thousands of ports, because at a smaller one the saving does not cover the cost of verification
02A homogeneous hardware environment, ideally one switch model
03Manufacturer-confirmed support for linear drive for the specific model and software version
04Short distances inside the facility, where the signal budget has a reserve
LPO is a risk or has no application
✕A multi-vendor environment. When switches from three manufacturers of different years work in the network, the benefit disappears under the weight of verifying every combination.
✕Coherent transmission at carrier distances. A 400G ZR+ module on a hundred-kilometre route needs full processing with dispersion compensation. That work cannot be moved to a router's ASIC.
This describes exactly one type of organisation, that is a large operator of computing infrastructure that buys switches in batches and has a team capable of carrying out its own hardware qualification. It is not by chance that the first production deployments of LPO are pilots at cloud operators. If, on the other hand, the goal is to reduce the power draw of the optical layer, and the network is multi-vendor, a greater effect comes from moving from a transponder architecture to coherent modules installed directly in routers. There the reduction in power draw reaches an order of magnitude, not twenty-odd percent.
A checklist before purchase
Whether the switch manufacturer confirms LPO support for the specific model and software version
What ASIC works in the switch and whether its SerDes supports linear drive
How many ports the deployment will cover and what annual energy saving that gives
Whether the environment is homogeneous in hardware, or multi-vendor
What distances and types of links LPO will cover
Whether there is the possibility of a pilot on a few percent of ports before a decision on scale
Who is responsible for diagnostics when a link behaves unstably
What the rollback path is if the pilot turns out badly
Whether LPO and DSP full modules are mutually interchangeable in the same ports
Whether the alternative of eliminating transponders instead of eliminating the DSP has been considered
LPO is a real technology with a real saving, but its range of applicability is narrow, that is large scale, homogeneous hardware, confirmed ASIC compatibility, and short distances. Beyond that range the cost of verification and the integration risk outweigh the benefit of a few watts per port. For most operators and integrators in Poland and the CEE region, a faster path to reducing the power draw of the optical layer remains the IPoDWDM architecture with coherent modules installed directly in routers.
The power-draw ranges given in the table are typical values for 800G modules available on the market, not the specification of a specific product. Before a purchasing decision the parameters should be verified in the datasheet of the chosen model, because the differences between manufacturers in this class reach a few watts.
FAQ
FAQ, linear optics LPO
LPO, that is linear drive, is an architecture in which the optical module has no DSP signal processor. The module becomes, in simplified terms, a linear amplifier driving the laser, and all the signal equalisation and error correction are taken over by the SerDes block in the host ASIC. Removing the DSP lowers the module's power draw by 25 to 30 percent, because it is precisely the DSP that consumes on average half the power of the whole module. For an 800G module the draw drops from the typical 20 to 30 W for DSP full to about 11 to 15 W for LPO. On a single module the saving is modest, but at a scale counted in thousands of ports it becomes a real item in the operating budget.
Under the assumptions of a thousand 800G ports, PUE 1.4, and an energy price of 0.12 EUR per kilowatt-hour, the DSP full variant at 20 W per module costs 29,434 EUR in energy per year, and the LPO variant at 13 W per module costs 19,132 EUR per year. The difference is 10,302 EUR per year, that is over 51 thousand EUR over five years. On top of that comes a lower purchase price of the module itself, usually by 15 to 25 percent, and less heat emission translating into cooling. One has to keep the proportion, however: ten thousand euro a year at a thousand ports is too little to justify integration risk where LPO is not fully verified. The technology takes on sense only at tens of thousands of ports.
There are three architectures, not two, though in sales conversations you usually hear only the opposition DSP versus LPO. DSP full has a full processor in the module and works in any device, you pay the full energy price for universality. LPO removes the DSP entirely and moves all the work to the host ASIC, giving the greatest saving but also the greatest requirements. LRO, that is retimed optics, is the intermediate variant: it removes the DSP from only one direction, retimes the signal where it is most needed, and saves where the host can cope. It is a sensible compromise between saving and integration risk, when full LPO is too risky and DSP full too energy-hungry.
Removing the DSP does not remove the work the DSP was doing, it only moves it to the host, which creates four requirements. First, the switch ASIC must support linear drive, and the list of compatible chips is markedly narrower than the list of devices supporting ordinary modules, so this is the first question to the switch manufacturer, not to the module supplier. Second, the electrical path between the ASIC and the port becomes part of the signal budget, so even two switches with the same ASIC but a different port layout may behave differently. Third, interoperability narrows, because the link behaviour depends on the host plus module pair on both sides. Fourth, diagnostics are harder, because a third possible cause of a problem is added, that is the equalisation settings on the host side.
LPO makes sense only when four conditions are met at once: scale in the thousands of ports, a homogeneous hardware environment with ideally one switch model, manufacturer-confirmed support for linear drive for the specific model and software version, and short distances inside the facility with a reserve in the signal budget. This describes exactly one type of organisation, that is a large operator of computing infrastructure that buys switches in batches and has a team capable of its own hardware qualification. It is not by chance that the first production deployments of LPO are pilots at cloud operators. In a multi-vendor environment, where switches from three manufacturers of different years work, the benefit disappears under the weight of verifying every combination.
No, and this is a hard boundary of application. A 400G ZR+ module operating on a hundred-kilometre route needs full signal processing with dispersion compensation and advanced error correction. That work cannot be moved to a router's ASIC, because its SerDes block is not designed for it. LPO works only on short distances inside the facility, where the signal budget has a reserve and the host SerDes task is realistic to perform. In the segment of coherent transmission at carrier distances, energy savings are achieved in an entirely different way, namely by eliminating transponders, not by eliminating the DSP.
If the goal is to lower the power draw of the optical layer and the network is multi-vendor, a greater effect comes from moving from a transponder architecture to coherent modules installed directly in routers, that is IPoDWDM. There the reduction in power draw reaches an order of magnitude, not twenty-odd percent as with LPO, and it does not require qualifying every host plus module combination. For most operators and integrators in Poland and the CEE region it is simply a faster and more certain path to energy savings. LPO remains a tool for a narrow group of large cloud operators with homogeneous hardware, not a universal answer to the question of lower power draw.
From a question to the switch manufacturer, not to the module supplier. First determine whether the manufacturer confirms LPO support for your specific model and software version, and what ASIC works in the device and whether its SerDes supports linear drive. Then calculate how many ports the deployment will cover and what annual saving that gives, and check whether the environment is homogeneous or multi-vendor. Plan a pilot on a few percent of ports before a decision on scale, establish who is responsible for diagnostics with an unstable link, and prepare a rollback path in case of a negative pilot. It is also worth immediately comparing LPO with the alternative of eliminating transponders, because in a multi-vendor network that is usually the better direction.
You already know why the quantum threat is real. Now one question: what to do in practice? Whether your organization needs QKD, when to start, and what to check before signing a contract with a vendor.
ZR standards are the technology that allowed companies to cut out external transponders and connect coherent optics directly to a router port. Less equipment, a lower energy bill, and more freedom when choosing partners.