The optical power budget step by step: the formula, two examples, common mistakes

The optical power budget is simple arithmetic that decides whether a link will work. It is calculated in ten minutes, and skipping it costs weeks of diagnosis after launch. The typical scenario looks like this: the module has a reach of 40 km in the catalogue, the route on the map is 35 km, so the order seems safe. After installation the link works unstably, because the real cable length turned out to be 47 km, and along the way there are also a multiplexer, six connectors, and ten splices. Below is the formula, two full numerical examples, and a list of the mistakes that recur most often.
The formula
The starting point is the difference between the power the module transmits and the power at which the receiver on the other side still reads the signal correctly. The available budget is the module's transmit power minus the receiver sensitivity. From this we subtract everything that attenuates the signal along the way, that is the fibre attenuation multiplied by the route length, the loss of the passive elements, the losses on connectors and splices, and the operational margin. What remains is the final margin. It must be positive, and in practice it should be at least 3 dB.
| Symbol | What it means | Typical value |
|---|---|---|
| P_TX | module transmit power | from the datasheet, in dBm |
| S_RX | receiver sensitivity | from the datasheet, in dBm |
| α | fibre attenuation per kilometre | 0.35 dB/km at 1310 nm, 0.22 dB/km at 1550 nm |
| L | route length along the cable | measured, not from a map |
| IL | loss of passive elements | DWDM multiplexer 3.5 dB, 1:32 splitter about 17 dB |
| n_c, a_c | number of connectors and loss per connector | 0.5 dB per connector |
| n_s, a_s | number of splices and loss per splice | 0.1 dB per splice |
| R | operational margin | 3 dB, on difficult routes 5 dB |
The fibre attenuation values are maxima for G.652.D fibre. Older G.652.A or B class fibre may have worse parameters, especially around 1383 nm. The operational margin is not a reserve just in case. It covers component ageing, future cable repairs with additional splices, and the degradation of connector parameters with subsequent re-matings.
Example one: a 10G point-to-point link over 40 km
A connection between two buildings, single-mode G.652.D fibre, an SFP+ 10G ER module operating at 1550 nm. The route along the cable is 40 km. The module parameters from the datasheet: transmit power minus 1 dBm, receiver sensitivity minus 22 dBm.
10G point-to-point, 40 km
SFP+ 10G ER, 1550 nm, G.652.D fibreThe link works with a comfortable reserve. Even two future cable repairs, each adding two splices and one connector, will use about 1.4 dB and will not threaten stability. It is worth noting what happens with the same module on a 60 km route. The fibre will take 13.2 dB, the total loss will be 19.4 dB, and the margin will drop to 1.6 dB. Formally the link will establish, but the first intervention on the cable will destabilise it. That is already a configuration in which a module of greater reach is needed.
Example two: an 80 km DWDM channel with an intermediate node
The same type of calculation, but in a DWDM path with a multiplexer on both sides and one intermediate node with an add-drop module. The route along the cable is 80 km, a DWDM 10G module operating at 1550 nm. The module parameters: transmit power plus 2 dBm, receiver sensitivity minus 24 dBm.
DWDM 80 km with an intermediate node
DWDM 10G, 1550 nm, multiplexer on both sidesThe link will not work. It is short by more than nine decibels, and no configuration on the hardware side will fix that. There are three ways out. The first is a module with higher transmit power and better sensitivity, which can give an extra 6 to 8 dB and still not be enough. The second is an EDFA optical amplifier, which solves the problem at the cost of an additional device and a worsening of the OSNR parameter. The third, most often the right one at such distances, is a coherent module, whose budget is incomparably larger and which additionally compensates for dispersion in the path. This example shows a rule worth remembering: in a DWDM path the passive elements can take more than the fibre itself. In this calculation the multiplexers and the add-drop module are 8.5 dB against 17.6 dB on the fibre, and the connectors and splices add another 6 dB.
The second limit: too strong a signal also does not work
The budget has two limits, not one. The lower one is the receiver sensitivity, that is the threshold below which the signal is too weak. The upper one is the overload level, above which the signal is too strong and the receiver stops reading the states correctly.
The power reaching the receiver must fall within the operating window
The budget has two limits, not one. The lower is sensitivity, below which the signal is too weak. The upper is overload, above which the signal is too strong and the receiver stops reading the states correctly. An 80-kilometre module on a two-kilometre route reaches the receiver practically untouched, so the link works seemingly correctly, but under load errors appear. The solution is to choose a module adequate to the route, not one of maximum reach just in case.
The problem appears in a specific situation, that is on a short section of fibre with a module of large reach. An 80-kilometre module plugged into a two-kilometre route transmits with a power that, after a short path, reaches the receiver practically untouched. The link may establish and work seemingly correctly, but under load errors will appear. In technologies with predefined budget classes, such as GPON or XGS-PON, this limit is written directly into the standard. The N1 class for XGS-PON covers loss from 14 to 29 dB, so a path with loss of 11 dB is outside the specification, though it intuitively seems safe. The solution is to choose a module adequate to the route, not a module of maximum reach just in case. A fixed attenuator is sometimes used as a stopgap, but it complicates maintenance and is one of the first elements forgotten during re-matings.
The eight most common mistakes
The route runs along streets, skirts obstacles, has slack in the closures. The real fibre length is often 20 to 40 percent greater than the geographical distance.
An as-built design from eight years ago does not account for three repairs that added six splices and two connectors along the way.
A path calculated down to the decibel will work on the day of launch and stop working after the first intervention on the cable.
In bidirectional paths on different wavelengths the attenuation differs significantly. At 1270 nm it is markedly higher than at 1577 nm. The budget is set by the worse direction.
A multiplexer's loss depends on the number of channels and the construction. A value from memory can differ by 2 dB, and with two devices in the path that is already 4 dB.
In a branched network the budget is calculated for the longest and most heavily loaded path, not for the typical one.
Checking whether the signal is not too weak, without checking whether it is not too strong.
The budget may add up and the module still not work, because the device does not recognise it or does not support the given management standard in the installed software version.
A sheet for calculating it yourself
The following set of data is enough to calculate any path. Copy it, fill in the values of your route, and substitute them into the formula.
Optical path budget sheet
fill in the middle column with the values of your route| Module transmit power | dBm | |
| Receiver sensitivity | dBm | |
| Receiver overload | dBm | |
| Route length along the cable | km | |
| Fibre attenuation | dB/km | |
| Multiplexer loss | dB | |
| Demultiplexer loss | dB | |
| Add-drop element loss | dB | |
| Number of connectors | pcs | |
| Number of splices | pcs | |
| Operational margin | 3 | dB |
If the margin comes out below 3 dB, the configuration needs correction, that is a shorter route, fewer passive elements, a module with a larger budget, or an amplifier.
When it is worth handing this to a specialist
A simple point-to-point link on verified fibre you can calculate yourself in a dozen or so minutes. It is worth using support when the path has intermediate nodes, when the network is branched, when coherent transmission is involved, or when you do not have current route measurements. Before every project we carry out a path measurement, a budget calculation for the worst case in each branch, and a recommendation of specific modules. The analysis is free and precedes the purchasing decision.
FAQ
FAQ, the optical power budget